• What will be affected the silent diesel generators

    What will be affected the silent diesel generators

    The use of silent generator set is greatly affected by the surrounding environment. When the environmental climate changes, the silent generator set will also change due to the change of environment. Therefore, when installing silent diesel generator set, we must take into account the impact of c...
    Read more
  • Fault detection method of speed control system of Cummins generator set

    Fault detection method of speed control system of Cummins generator set

    Turn on the power switch of the control box of Cummins generator set. When there are two quick, crisp and small sounds, the speed control system is basically normal; If there is no sound, it may be that the speed control board has no output or the actuator is rusted and stuck. (1) Fault detection...
    Read more
  • Five functions of engine oil on diesel generator set

    Five functions of engine oil on diesel generator set

    1. Lubrication: as long as the engine is running, the internal parts will produce friction. The faster the speed is, the more intense the friction will be. For example, the temperature of the piston can be more than 200 degrees Celsius. At this time, if there is no diesel generator set with oil, ...
    Read more
  • What are the effects of water temperature on diesel generator sets?

    What are the effects of water temperature on diesel generator sets?

    ▶ First, the temperature is low, the diesel combustion conditions in the cylinder deteriorate, the fuel atomization is poor, the combustion period after ignition increases, the engine is easy to work rough, aggravate the damage of crankshaft bearings, piston rings and other parts, reduce power an...
    Read more
  • How to overhaul the radiator of diesel generator?

    How to overhaul the radiator of diesel generator?

    1. The main fault of water radiator is water leakage. The main causes of water leakage are: the blade of the fan is broken or tilted during operation, resulting in the damage of the heat sink; The radiator is not fixed properly, which causes the radiator joint to crack during the operation of the...
    Read more
  • How to correctly replace the engine oil of diesel generator set?

    How to correctly replace the engine oil of diesel generator set?

    1. Place the generator set in a plane and start the engine for a few minutes to increase the fuel temperature and then stop the engine. 2. Remove the down-filling bolt (i.e. fuel scale). 3. Place an fuel basin under the engine and remove the fuel draining screw so that the fuel can be discharged ...
    Read more
  • Why can’t the diesel generator be unloaded for a long time

    Why can’t the diesel generator be unloaded for a long time

    Why can’t the diesel generator be unloaded for a long time? The main considerations are: If it is operated below 50% of the rated power, the oil consumption of diesel generator set will increase, the diesel engine will be easy to deposit carbon, increase the failure rate and shorten the ove...
    Read more
  • How to judge the quality of a diesel generator?

    How to judge the quality of a diesel generator?

    Distinguish the quality of diesel generator set from the following aspects: 1. Look at the sign and appearance of the generator. See which factory produced it, when it was delivered, and how long it is from now; See whether the paint on the surface falls off, whether the parts are damaged, whethe...
    Read more
  • Cleaning and inspection of exhaust gas turbocharger of diesel generator

    Cleaning and inspection of exhaust gas turbocharger of diesel generator

    Cleaning of exhaust gas turbocharger of diesel generator ① It is not allowed to use corrosive cleaning solution to clean all parts. ② Soak the carbon and sediment on the parts in the cleaning solution to make them soft. Among them, the middle bright return fuel is light, and the dirt at the turbi...
    Read more
  • How to Reduce Environmental Noise Diesel Generator Set

    How to Reduce Environmental Noise Diesel Generator Set

    During the working process of diesel generator set, a small amount of waste and solid particles are produced, the main hazard is noise, whose sound value is about 108 dB, which seriously affects people’s normal work and life. In order to solve this environmental pollution, Leton power has d...
    Read more
  • What is the difference between generator with brush and brushless?

    What is the difference between generator with brush and brushless?

    1. Principle difference: brush motor adopts mechanical commutation, magnetic pole does not move, cfuel rotates. When the motor works, the cfuel and commutator rotate, the magnet and carbon brush do not rotate, and the alternating change of cfuel current direction is accomplished by the commutator...
    Read more
  • What are the advantages of silent generators?

    What are the advantages of silent generators?

    As China’s serious power problems become more and more prominent, people have higher and higher requirements for environmental protection. Diesel generator set with electrostatic loudspeaker, as the standby power supply of power grid, has been widely used because of its low noise, especiall...
    Read more
  • What are the functional differences between automatic and automatic switching of diesel generator sets?

    What are the functional differences between automatic and automatic switching of diesel generator sets?

    There are two statements about the automatic operation of diesel generator set. One is automatic system switching ATS, i.e. automatic system switching-back without manual operation. However, the automatic system switchgear must be added to the frame of automatic controller to complete the automat...
    Read more
  • Auto start function of generator set

    Auto start function of generator set

    SAMRTGEN Hgm6100nc series power station automation controller integrates digital, intelligent and network technology, which is used in the automation and monitoring system of a single generator set to realize the automatic startup / shutdown, data measurement, alarm protection and “three re...
    Read more
  • Six protective measures for diesel generator after being drenched by rain

    Six protective measures for diesel generator after being drenched by rain

    Continuous torrential rain in summer, some generator sets used outdoors are not covered in time in rainy days, and the diesel generator set is wet. If they are not taken care of in time, the generator set will be rusted, corroded and damaged, the circuit will be damp in case of water, the insulat...
    Read more
  • How to shut down the diesel generator set and which circumstances require emergency shutdown?

    How to shut down the diesel generator set and which circumstances require emergency shutdown?

    Taking large sets as an example, it is described as follows: 1. Gradually remove the load, disconnect the load switch, and turn the machine change switch to the manual position; 2. When the speed drops to 600 ~ 800 RPM under no-load, push the handle of the oil pump to stop oil supply after runnin...